★ New disk can not add to uis storage pool after fault disk changed (error controller has data in cache for offline or missing virtual disks )

2024-10-12 15:39:47 Published
  • 0 Followed
  • 0Collected ,2537Browsed

Network Topology

NULL

Problem Description

can not create raid 0 for new disk, error shows: Description = controller has data in cache for offline or missing virtual disks


Process Analysis

1. check the  preservedCache of the abnormal controller    


2.delete the abnormal preservedCache


Solution

1.Run the./storcli64 /c1 show preservedCache command to check whether preservedcache exists. For example, the command output shows that logical disks are missing

2.Run ./storcli64 / c1/vxx delete preservedCache Deletes the existing preservedcache and reconfigs the storage array.

Please rate this case:   
0 Comments

No Comments

Add Comments: